AI carbon footprint in EU West - France: emissions per token and per query

    Factor version soma-ai-ef-2026.10-dataset-v3.0.0. Last updated . Location-based grid averages, not renewable contracts. Estimates from published benchmarks.

    Part of the SOMA AI Emission Factors cluster.

    How much CO₂ does an AI query emit when served from EU West - France?

    A 1210-token query to a class B model (gpt-4o) served from EU West - France emits about 0.011 g CO₂e, and a million tokens emit 0.0082 kg CO₂e.

    Rank 2 of 16 for class B, lowest carbon first (full table). 1.1x the level of EU North - Sweden, Asia Pacific - Singapore is 4.9x higher.

    Which grid supplies the electricity in EU West - France?

    EU West - France maps to France, a national grid, at 53.3 g CO₂e per kWh for 2023. That is 0.2 times the EU-27 average (236 g) and 0.1 times the global average (483.2 g). The source is Ember yearly electricity data, CO2 intensity 2023, 53.26 g/kWh (lifecycle, IPCC AR5).

    Cloud regions on this grid, 4 in all (1 AWS, 2 Azure, 1 Google Cloud).

    Grid FRA.
    ProviderRegion idRegion nameLocationMapping confidenceMapping note
    AWSeu-west-3Europe (Paris)Parishigh
    AzurefrancecentralFrance CentralParishigh
    AzurefrancesouthFrance SouthMarseillehighAccess restricted by Microsoft to specific customer scenarios (e.g. disaster recovery); listed on the official page but not open to general new subscriptions.
    Google Cloudeurope-west9europe-west9Paris, Francehigh

    Which grids have an intensity close to France?

    Closest grids to 53.3 g CO₂e per kWh, with the ratio to the France figure.
    Difference gGridCodeg CO₂e per kWhRatio
    1.3MalawiMWI54.61.024
    5.6UgandaUGA58.91.105
    -5.7NamibiaNAM47.60.893
    -5.7Sierra LeoneSLE47.60.893
    -14.9SwedenSWE38.40.720
    -18.5SwitzerlandCHE34.80.653
    21.1TajikistanTJK74.41.396
    -22.8NorwayNOR30.50.572
    -25.5IcelandISL27.80.522
    -26.4Congo (the Democratic Republic of the)COD26.90.505

    Emission factors for EU West - France by model class

    Per million tokens unless stated, per query = 1210 tokens.
    Model classElectricity kgHardware kgConstruction kgTraining kgTotal kg CO₂eg per queryWater LmL per query
    Class A (small)0.001160.000270.000140.000600.0020.00290.0810.11
    Class B (mid-size)0.003800.001010.000460.002930.0080.0110.2640.36
    Class C (frontier)0.014140.003880.001690.012840.0330.0430.9821.4
    kg CO₂e per million tokens, development shown apart.
    Model classCentralClass range lowClass range highHigh caseB200Development
    Class A0.0021710.0015250.0029330.0030450.0019950.001581
    Class B0.0081980.0061270.0096840.011090.0067720.005178
    Class C0.032560.019650.042850.043380.033080.01928

    How much does siting matter for a model served from EU West - France?

    Electricity is 46.3% of the class B total here (class A 53.4%, class C 43.4%), with hardware at 12%, construction 5.6% and training 36%. A cleaner grid shrinks the electricity term, while the other 53.7% stays put.

    The example company (2,323 million class B tokens a year) emits 19 kg CO₂e from EU West - France. Moving to EU North - Sweden would save 2.5 kg (13%).

    Kilograms CO₂e a year saved by moving the example traffic from EU West - France to each region, by model class.
    RegionGrid g per kWhClass AClass BClass C
    EU North - Sweden38.40.7512.469.15

    How much water does AI usage consume in EU West - France?

    A class B query of 1210 tokens from EU West - France consumes about 0.36 mL of water and a million tokens 0.264 litres, or 0.149 litres without the water attributed to hydropower.

    Water inputs.
    InputValue
    On-site WUE, L per kWh0.05
    WUE denominatorIT load
    WUE basis as publishedwithdrawal
    Withdrawal to consumption0.6667
    EWIF, L per kWh3.671
    EWIF without hydro, L per kWh2.061
    AWARE factor4.99
    Confidencecontinental
    SourceAWS; AWS Europe aggregate; 2025
    Water per million tokens in litres.
    Model classOn siteGrid electricityTotalTotal without hydroAWARE-weighted on site
    Class A0.0006050.07990.08050.04550.00302
    Class B0.001980.2620.2640.1490.00988
    Class C0.007370.9750.9820.5540.0368

    Where do these numbers come from and how do I cite them?

    Figures per query are one plain exchange, before the Tier 2b reasoning uplift. Electricity term. GPU energy per token from the ML.ENERGY Leaderboard v3, a facility overhead of 1.20, and grid carbon intensity from EPA eGRID 2023 and Ember 2023. Embodied hardware, data-centre construction and amortised training terms are documented on the methodology page. Water combines on-site cooling water (Li et al. 2025) with the water embedded in grid electricity (Reig et al. 2020). The modelled range of the models inside a class, around the class value, is −41% to +48% for class A, −39% to +24% for class B and −67% to +55% for class C.

    Dataset: AI Inference Emission and Resource Factors for Corporate GHG Inventories (SOMA AI Emission Factors (SAEF)), Llopis-Garcia, G., SOMA AI, 19 October 2026, CC BY 4.0, concept DOI 10.5281/zenodo.20443585, which resolves to the latest version (this version 10.5281/zenodo.23371447, earlier version 2 values at 10.5281/zenodo.22767475). Method: Accounting for Purchased AI Inference in Corporate GHG Inventories: A Token-Based Method, arXiv:2606.10660, under peer review.

    Partners can fetch any row from the AI factors API, and the whole table is a CSV download.

    Cite as "0.0082 kg CO₂e per million tokens, class B, EU West - France, SAEF, 19 October 2026" and link somaai.earth/ai-footprint/factors/eu-france.

    Keep reading