How much energy and CO2e does one second of AI video use?
SOMA AI's SAEF dataset (v3.5.0) estimates one second of 720p video from a standard-tier video model (class B) at 83 Wh of facility energy and 25 g CO2e in eu-west-1, with a range of 22 to 340 Wh. A fast or lite tier (class A) is estimated at 24 Wh per second and a pro or quality tier (class C) at 210 Wh, so an 8-second class B clip comes to about 0.66 kWh.
These video values are indicative. The serving factor of 0.5 (range 0.2 to 1.0) and the resolution multipliers are assumptions, and they move every value. No provider publishes energy for video generation and the class of a closed model is assigned from its price per second. For the published research figures, see how much energy AI image and video generation use.
What are the SAEF factors per second, by resolution?
| Row and unit | Facility Wh | g CO2e, eu-west-1 | g CO2e, us-east-1 |
|---|---|---|---|
| Class A (fast and lite tiers), 480p, per second | 1.1 / 9.4 / 35 | 0.32 / 2.8 / 10 | 0.34 / 3.0 / 11 |
| Class A (fast and lite tiers), 720p, per second | 4.8 / 24 / 77 | 1.4 / 7.1 / 23 | 1.5 / 7.6 / 25 |
| Class A (fast and lite tiers), 1080p, per second | 5.8 / 53 / 330 | 1.7 / 16 / 100 | 1.9 / 17 / 110 |
| Class A (fast and lite tiers), 2160p, per second | 9.6 / 71 / 770 | 2.9 / 21 / 230 | 3.1 / 23 / 250 |
| Class B (standard tiers), 480p, per second | 4.8 / 33 / 150 | 1.4 / 9.9 / 46 | 1.5 / 11 / 49 |
| Class B (standard tiers), 720p, per second | 22 / 83 / 340 | 6.5 / 25 / 100 | 7.0 / 27 / 110 |
| Class B (standard tiers), 1080p, per second | 26 / 190 / 1,500 | 7.8 / 56 / 440 | 8.4 / 60 / 470 |
| Class B (standard tiers), 2160p, per second | 43 / 250 / 3,400 | 13 / 75 / 1,000 | 14 / 80 / 1,100 |
| Class C (pro and quality tiers, unmapped models), 480p, per second | 18 / 83 / 380 | 5.5 / 25 / 110 | 5.9 / 27 / 120 |
| Class C (pro and quality tiers, unmapped models), 720p, per second | 83 / 210 / 840 | 25 / 62 / 250 | 27 / 67 / 270 |
| Class C (pro and quality tiers, unmapped models), 1080p, per second | 99 / 460 / 3,600 | 30 / 140 / 1,100 | 32 / 150 / 1,200 |
| Class C (pro and quality tiers, unmapped models), 2160p, per second | 170 / 620 / 8,400 | 50 / 190 / 2,500 | 53 / 200 / 2,700 |
| Row and unit | Facility Wh | g CO2e, eu-west-1 | g CO2e, us-east-1 |
|---|---|---|---|
| Class A, 8-second clip at 720p | 38 / 190 / 620 | 12 / 57 / 190 | 12 / 61 / 200 |
| Class B, 8-second clip at 720p | 170 / 660 / 2,700 | 52 / 200 / 810 | 56 / 210 / 870 |
| Class C, 8-second clip at 720p | 660 / 1,700 / 6,800 | 200 / 500 / 2,000 | 210 / 530 / 2,200 |
Classes follow the price per second at 720p, as the text classes follow price tiers: up to 0.12 USD per second is class A, 0.12 to 0.30 class B and above 0.30 class C, and every unmapped video identifier is class C. Class C has no open model with published energy, so it is class B times 2.5.
Which assumptions move every video value?
- The serving factor. The anchors are open models run as released, with 50 denoising steps. Production services use step distillation, guidance distillation, lower precision and caching, and the extent is undisclosed. SAEF scales the anchors by a serving factor of 0.5, with 0.2 as the low and 1.0 as the high case. It multiplies every video row by the same amount.
- Resolution multipliers. On the 720p value, 480p is 0.40 times, 1080p 2.25 times and 2160p 3.0 times in the central case. The 1080p and 2160p rows are the widest, because the low case follows provider prices that rise far less than pixels, and the high case scales super-linearly.
- The class step. Class B is 3.5 times class A and class C is 2.5 times class B at 720p, so assigning a model to a class by price is the single biggest choice an inventory makes.
- Evidence. The measured inputs are GPU energy per video for four open text-to-video models. Image-to-video uses the text-to-video values. The evidence supports one significant figure, so read the values on this page as one significant figure, printed at two for traceability.
How does a second of video compare with a text prompt?
For scale, one text chat exchange with a class B (mid-size) model, 928 input and 282 output tokens uses 0.099 Wh and 0.030 g CO2e in eu-west-1, counted on the same basis with training left out. One second of class B 720p video is about 840 times that energy and one second of class A 720p video about 240 times. An 8-second class B clip is about 6,700 text exchanges. See the per-image page for the image figures on the same basis.
How do I estimate my own video usage?
- Convert the export to seconds. Veo and Gemini Omni bill seconds by resolution, and so did Sora, whose API shut down on 24 September 2026 (historical exports only). Runway credits convert at the credits per second of the model, and per-clip billing converts at the clip duration. With only a clip count, use 8 seconds per clip.
- Set the resolution tier. 480p covers 360p and 540p, 720p covers 0.5 to 1.2 megapixels, 1080p covers 1.2 to 2.5 megapixels and 2160p anything above. If the export has no resolution, use 720p.
- Assign the class. Use the price per second at 720p, with class A up to 0.12 USD, class B up to 0.30 USD and class C above that or unknown.
- Multiply and keep the range. Multiply seconds by the central, low and high values and report all three. Show 1080p and 2160p with their range.
- Disclose what is out. State that training is excluded, that the serving factor is an assumption and that free drafts and failed generations are missing.
Worked example: 100 class B clips of 8 seconds at 720p is 66 kWh of facility energy (range 17 to 270 kWh) and 20 kg CO2e in eu-west-1 (range 5.2 to 81 kg), or 21 kg in us-east-1.
What does this page not claim?
- That these figures are measurements of a provider's video service. They are SAEF estimates, and every value is indicative.
- That the serving factor or the resolution multipliers are known. They are assumptions and are stated as such in the dataset.
- That training is included. No training term is charged for any non-text model type.
- That clips of 20 seconds or more are well covered. The per-second unit understates them.
Where do the figures come from, and how should they be cited?
Dataset: AI Inference Emission and Resource Factors for Corporate GHG Inventories (SOMA AI Emission Factors, SAEF), Llopis-Garcia, G., SOMA AI, version 3.5.0, published 27 November 2026, Zenodo record 10.5281/zenodo.24596349, concept DOI 10.5281/zenodo.20443585 (resolves to the latest version). The rows used here are in modality_factors.csv and the method is in MODALITIES_METHOD.md, both in the deposit. Licence: SOMA AI Emission Factors Data Licence 1.0 (Non-Commercial).
The text method behind the comparison figures is published as Llopis-Garcia (2026), Sustainable Production and Consumption 70:320-347, doi:10.1016/j.spc.2026.11.003. The non-text rows come from the dataset method file above, not from that paper.
Energy inputs and billing facts used for these rows (ids as in modality_sources.csv):
- R2-S02: ML.ENERGY Leaderboard v3, text-to-video task data (Apache-2.0)
- R2-S03: Delavande, Pierrard and Luccioni (2025), Video Killed the Energy Budget, arXiv:2509.19222 (CC BY 4.0)
- R2-S13: Vertex AI generative AI pricing, Veo section (provider documentation, facts only)
- R1-S01: SAEF v3.3.0 text factors, built on the ML.ENERGY Leaderboard v3 lm-arena-chat data (SOMA AI Emission Factors Data Licence 1.0 (Non-Commercial))
Method, API and the full table: methodology, AI factors API, SAEF.
Short answers
- How much energy does AI video generation use per second?
- SOMA AI's SAEF dataset (v3.5.0) estimates 83 Wh of facility energy per second of 720p video from a standard-tier model (class B), with a range of 22 to 340 Wh, and 24 Wh for a fast or lite tier (class A). The value is indicative, because the serving factor and the resolution multipliers are assumptions.
- How much CO2 does an AI video clip produce?
- An 8-second class B clip at 720p is estimated at 660 Wh and 200 g CO2e in eu-west-1 (range 52 to 810 g). The figure counts electricity, embodied hardware and data-centre construction, leaves training out, and is an estimate, not a measurement of any provider.
- Why is the video range so wide?
- Every value rests on a serving factor of 0.5 (range 0.2 to 1.0) that scales open-model measurements down to a production service, and on resolution multipliers, and both are assumptions. At 1080p the class B range runs from 26 to 1,500 Wh per second, a factor of 56. Show 1080p and 2160p with their range or not at all.
- Is video worse than text or images?
- Per item, yes by orders of magnitude. One second of class B 720p video is about 840 times the energy of one text exchange with a class B model (928 input and 282 output tokens) and a class B 8-second clip is about 6,700 times.
- Does the figure include audio, failed generations or long clips?
- The unit is one second of generated video including any audio track the model generates with it. Free drafts, failed generations and moderated requests are in no billing export and are not counted. Energy grows faster than clip length, so clips of 20 seconds or more are understated.
Keep reading
- What is the carbon footprint of AI by model type: text, image, video, voice and embeddings? Every model type in one table
- How much energy and CO2e does one AI-generated image use? Per image, by class and quality
- How much energy does generating an AI image or video use? Published research figures for image and video
- How SOMA calculates the carbon and water footprint of AI usage. The text method and its data tiers