AI carbon footprint in EU West - Ireland: emissions per token and per query

Factor version soma-ai-ef-2026.11-dataset-v3.1.0. Factors last updated . Location-based grid averages, not renewable contracts. Estimates from published benchmarks.

Page updated

Part of the SOMA AI Emission Factors cluster.

How much CO₂ does an AI query emit when served from EU West - Ireland?

A 1210-token query to a class B model (gpt-4o) served from EU West - Ireland emits about 0.033 g CO₂e, and a million tokens emit 0.0245 kg CO₂e.

Rank 8 of 16 for class B, lowest carbon first (full table). 3.4x the level of EU North - Sweden, Asia Pacific - Singapore is 1.6x higher.

Which grid supplies the electricity in EU West - Ireland?

EU West - Ireland maps to Ireland, a national grid, at 282.5 g CO₂e per kWh for 2023. That is 1.2 times the EU-27 average (236 g) and 0.6 times the global average (483.2 g). The source is Ember yearly electricity data, CO2 intensity 2023, 282.5 g/kWh (lifecycle, IPCC AR5).

Cloud regions on this grid, 2 in all (1 AWS, 1 Azure).

Grid IRL.
ProviderRegion idRegion nameLocationMapping confidenceMapping note
AWSeu-west-1Europe (Ireland)IrelandhighProvider states country only.
AzurenortheuropeNorth EuropeIrelandhighProvider states country only (Ireland).

The note for AWS eu-west-1 reads "Provider states country only.".

Which grids have an intensity close to Ireland?

Closest grids to 282.5 g CO₂e per kWh, with the ratio to the Ireland figure.
Difference gGridCodeg CO₂e per kWhRatio
-4.2FijiFJI278.30.985
-5.8NPCC New EnglandNEWE276.70.979
9.3PeruPER291.81.033
12.6LiberiaLBR295.11.045
-14.3NetherlandsNLD268.20.949
-16.3ASCC MiscellaneousAKMS266.20.942
-16.3PanamaPAN266.20.942
18.4NicaraguaNIC300.91.065
-20.1ArmeniaARM262.40.929
21.3SERC Virginia/CarolinaSRVC303.81.075

Emission factors for EU West - Ireland by model class

Per million tokens unless stated, per query = 1210 tokens.
Model classElectricity kgHardware kgConstruction kgTraining kgTotal kg CO₂eg per queryWater LmL per query
Class A (small)0.006150.000270.000140.000600.0070.00980.0320.045
Class B (mid-size)0.020140.001010.000460.002930.0250.0330.1060.15
Class C (frontier)0.074990.003880.001690.012840.0930.130.3950.55
kg CO₂e per million tokens, development shown apart.
Model classCentralClass range lowClass range highHigh caseB200Development
Class A0.0071610.0045060.010280.011290.0063160.008386
Class B0.024540.01620.029480.038090.017650.02746
Class C0.093420.039840.13710.14390.095890.1023

How much does siting matter for a model served from EU West - Ireland?

Electricity is 82.1% of the class B total here (class A 85.9%, class C 80.3%), with hardware at 4.1%, construction 1.9% and training 12%. Electricity carries most of the 0.0245 kg, so the grid is the biggest lever.

The example company (2,323 million class B tokens a year) emits 57 kg CO₂e from EU West - Ireland. Moving to Netherlands would save 2.4 kg (4.2%) or EU West - UK (London) would save 7.8 kg (14%).

Kilograms CO₂e a year saved by moving the example traffic from EU West - Ireland to each region, by model class.
RegionGrid g per kWhClass AClass BClass C
Netherlands268.20.7252.378.84
EU West - UK (London)235.62.377.7728.9

How much water does AI usage consume in EU West - Ireland?

A class B query of 1210 tokens from EU West - Ireland consumes about 0.15 mL of water and a million tokens 0.106 litres, or 0.0815 litres without the water attributed to hydropower.

Water inputs.
InputValue
On-site WUE, L per kWh0.02
WUE denominatorIT load
WUE basis as publishedwithdrawal
Withdrawal to consumption0.6667
EWIF, L per kWh1.476
EWIF without hydro, L per kWh1.132
AWARE factor1.17
Confidencepublished-site
SourceAWS; AWS Region Europe (Ireland) eu-west-1; 2025
Water per million tokens in litres.
Model classOn siteGrid electricityTotalTotal without hydroAWARE-weighted on site
Class A0.0002420.03210.03240.02490.000283
Class B0.0007920.1050.1060.08150.000927
Class C0.002950.3920.3950.3030.00345

Where do these numbers come from and how do I cite them?

Figures per query are one plain exchange, before the Tier 2b reasoning uplift. Electricity term. GPU energy per token from the ML.ENERGY Leaderboard v3, a facility overhead of 1.20, and grid carbon intensity from EPA eGRID 2023 and Ember 2023. Embodied hardware, data-centre construction and amortised training terms are documented on the methodology page. Water combines on-site cooling water (Li et al. 2025) with the water embedded in grid electricity (Reig et al. 2020). The modelled range of the models inside a class, around the class value, is −41% to +48% for class A, −39% to +24% for class B and −67% to +55% for class C.

Dataset: AI Inference Emission and Resource Factors for Corporate GHG Inventories (SOMA AI Emission Factors (SAEF)), Llopis-Garcia, G., SOMA AI, 12 November 2026, CC BY 4.0, concept DOI 10.5281/zenodo.20443585, which resolves to the latest version (this version 10.5281/zenodo.24160409, earlier version 2 values at 10.5281/zenodo.22767475). Method: Accounting for Purchased AI Inference in Corporate GHG Inventories: A Token-Based Method, arXiv:2606.10660, accepted for publication in Sustainable Production and Consumption.

Partners can fetch any row from the AI factors API, and the whole table is a CSV download.

Cite as "0.0245 kg CO₂e per million tokens, class B, EU West - Ireland, SAEF, 12 November 2026" and link somaai.earth/ai-footprint/factors/eu-ireland.

Keep reading