AI carbon footprint in EU West - UK (London): emissions per token and per query

    Factor version soma-ai-ef-2026.10-dataset-v3.0.0. Last updated . Location-based grid averages, not renewable contracts. Estimates from published benchmarks.

    Part of the SOMA AI Emission Factors cluster.

    How much CO₂ does an AI query emit when served from EU West - UK (London)?

    A 1210-token query to a class B model (gpt-4o) served from EU West - UK (London) emits about 0.029 g CO₂e, and a million tokens emit 0.0212 kg CO₂e.

    Rank 6 of 16 for class B, lowest carbon first (full table). 3.0x the level of EU North - Sweden, Asia Pacific - Singapore is 1.9x higher.

    Which grid supplies the electricity in EU West - UK (London)?

    EU West - UK (London) maps to United Kingdom, a national grid, at 235.6 g CO₂e per kWh for 2023. That is 1.0 times the EU-27 average (236 g) and 0.5 times the global average (483.2 g). The source is Ember yearly electricity data, CO2 intensity 2023, 235.6 g/kWh (lifecycle, IPCC AR5).

    Cloud regions on this grid, 4 in all (1 AWS, 2 Azure, 1 Google Cloud).

    Grid GBR.
    ProviderRegion idRegion nameLocationMapping confidenceMapping note
    AWSeu-west-2Europe (London)Londonhigh
    AzureuksouthUK SouthLondonhigh
    AzureukwestUK WestCardiffhigh
    Google Cloudeurope-west2europe-west2London, Englandhigh

    Which grids have an intensity close to United Kingdom?

    Closest grids to 235.6 g CO₂e per kWh, with the ratio to the United Kingdom figure.
    Difference gGridCodeg CO₂e per kWhRatio
    -3.5Lao People's Democratic Republic (the)LAO232.10.985
    7.6RomaniaROU243.21.032
    9.3French GuianaGUF244.91.039
    -10.5SloveniaSVN225.10.955
    -11.2CameroonCMR224.40.952
    14.4Cook Islands (the)COK2501.061
    -16.5WECC CaliforniaCAMX219.10.930
    22.8ColombiaCOL258.41.097
    26.8ArmeniaARM262.41.114
    30.6ASCC MiscellaneousAKMS266.21.130

    Emission factors for EU West - UK (London) by model class

    Per million tokens unless stated, per query = 1210 tokens.
    Model classElectricity kgHardware kgConstruction kgTraining kgTotal kg CO₂eg per queryWater LmL per query
    Class A (small)0.005130.000270.000140.000600.0060.00840.0530.073
    Class B (mid-size)0.016800.001010.000460.002930.0210.0290.1730.24
    Class C (frontier)0.062540.003880.001690.012840.0810.110.6440.89
    kg CO₂e per million tokens, development shown apart.
    Model classCentralClass range lowClass range highHigh caseB200Development
    Class A0.006140.0038960.0087770.0096030.0054320.006994
    Class B0.02120.014140.025340.032570.015420.0229
    Class C0.080970.035710.11780.12330.083030.08529

    How much does siting matter for a model served from EU West - UK (London)?

    Electricity is 79.2% of the class B total here (class A 83.5%, class C 77.2%), with hardware at 4.8%, construction 2.1% and training 14%. Electricity carries most of the 0.0212 kg, so the grid is the biggest lever.

    The example company (2,323 million class B tokens a year) emits 49 kg CO₂e from EU West - UK (London). Moving to EU South - Spain would save 11 kg (22%) or EU West - Belgium would save 17 kg (34%).

    Kilograms CO₂e a year saved by moving the example traffic from EU West - UK (London) to each region, by model class.
    RegionGrid g per kWhClass AClass BClass C
    EU South - Spain169.73.3310.940.7
    EU West - Belgium134.75.116.762.2

    How much water does AI usage consume in EU West - UK (London)?

    A class B query of 1210 tokens from EU West - UK (London) consumes about 0.24 mL of water and a million tokens 0.173 litres, or 0.137 litres without the water attributed to hydropower.

    Water inputs.
    InputValue
    On-site WUE, L per kWh0.14
    WUE denominatorIT load
    WUE basis as publishedwithdrawal
    Withdrawal to consumption0.6667
    EWIF, L per kWh2.347
    EWIF without hydro, L per kWh1.850
    AWARE factor2.29
    Confidencepublished-site
    SourceAWS; AWS Region Europe (London) eu-west-2; 2025
    Water per million tokens in litres.
    Model classOn siteGrid electricityTotalTotal without hydroAWARE-weighted on site
    Class A0.001690.05110.05280.0420.00388
    Class B0.005540.1670.1730.1370.0127
    Class C0.02060.6230.6440.5120.0473

    Where do these numbers come from and how do I cite them?

    Figures per query are one plain exchange, before the Tier 2b reasoning uplift. Electricity term. GPU energy per token from the ML.ENERGY Leaderboard v3, a facility overhead of 1.20, and grid carbon intensity from EPA eGRID 2023 and Ember 2023. Embodied hardware, data-centre construction and amortised training terms are documented on the methodology page. Water combines on-site cooling water (Li et al. 2025) with the water embedded in grid electricity (Reig et al. 2020). The modelled range of the models inside a class, around the class value, is −41% to +48% for class A, −39% to +24% for class B and −67% to +55% for class C.

    Dataset: AI Inference Emission and Resource Factors for Corporate GHG Inventories (SOMA AI Emission Factors (SAEF)), Llopis-Garcia, G., SOMA AI, 19 October 2026, CC BY 4.0, concept DOI 10.5281/zenodo.20443585, which resolves to the latest version (this version 10.5281/zenodo.23371447, earlier version 2 values at 10.5281/zenodo.22767475). Method: Accounting for Purchased AI Inference in Corporate GHG Inventories: A Token-Based Method, arXiv:2606.10660, under peer review.