AI carbon footprint in US Central - Iowa: emissions per token and per query
Factor version soma-ai-ef-2026.10-dataset-v3.0.0. Last updated . Location-based grid averages, not renewable contracts. Estimates from published benchmarks.
Part of the SOMA AI Emission Factors cluster.
How much CO₂ does an AI query emit when served from US Central - Iowa?
A 1210-token query to a class B model (gpt-4o) served from US Central - Iowa emits about 0.052 g CO₂e, and a million tokens emit 0.0381 kg CO₂e.
Rank 14 of 16 for class B, lowest carbon first (full table). 5.3x the level of EU North - Sweden, Asia Pacific - Singapore is 1.1x higher.
Which grid supplies the electricity in US Central - Iowa?
US Central - Iowa maps to MRO West, a US eGRID subregion, at 472.1 g CO₂e per kWh for 2023. That is 2.0 times the EU-27 average (236 g) and 1.0 times the global average (483.2 g). The source is eGRID2023 MROW 926.6 lb/MWh CO2e total output x 1.1232 (Ember lifecycle basis).
Cloud regions on this grid, 2 in all (1 Azure, 1 Google Cloud).
| Provider | Region id | Region name | Location | Mapping confidence | Mapping note |
|---|---|---|---|---|---|
| Azure | centralus | Central US | Iowa | high | Provider states state only; polygon test at West Des Moines (41.60,-93.70) = MROW. Same subregion as GCP us-central1 (Council Bluffs). CONFIRMED 2026-10-14 by Data Center Map (datacentermap.com, operator pages for Microsoft and Amazon AWS, read 14 October 2026): Microsoft Ginger East campus, West Des Moines (29 listings); polygon test at West Des Moines (41.58,-93.71) = MROW; agrees with the assumed site, confidence raised from medium to high. |
| Google Cloud | us-central1 | us-central1 | Council Bluffs, Iowa | high | Subregion settled in paper (anchor). |
The note for Google Cloud us-central1 reads "Subregion settled in paper (anchor).".
Which grids have an intensity close to MRO West?
| Difference g | Grid | Code | g CO₂e per kWh | Ratio |
|---|---|---|---|---|
| 2.6 | Viet Nam | VNM | 474.7 | 1.006 |
| -5.4 | RFC West | RFCW | 466.7 | 0.989 |
| 7.9 | Cabo Verde | CPV | 480 | 1.017 |
| -11.0 | ASCC Alaska Grid | AKGD | 461.1 | 0.977 |
| 11.7 | United Arab Emirates | ARE | 483.8 | 1.025 |
| -11.9 | SERC Tennessee Valley | SRTV | 460.2 | 0.975 |
| 12.8 | Macao | MAC | 484.9 | 1.027 |
| 16.9 | Mexico | MEX | 489 | 1.036 |
| 19.1 | Cambodia | KHM | 491.2 | 1.040 |
| -19.4 | Ghana | GHA | 452.7 | 0.959 |
Emission factors for US Central - Iowa by model class
| Model class | Electricity kg | Hardware kg | Construction kg | Training kg | Total kg CO₂e | g per query | Water L | mL per query |
|---|---|---|---|---|---|---|---|---|
| Class A (small) | 0.01028 | 0.00027 | 0.00014 | 0.00060 | 0.011 | 0.016 | 0.069 | 0.096 |
| Class B (mid-size) | 0.03365 | 0.00101 | 0.00046 | 0.00293 | 0.038 | 0.052 | 0.227 | 0.31 |
| Class C (frontier) | 0.12532 | 0.00388 | 0.00169 | 0.01284 | 0.144 | 0.2 | 0.846 | 1.2 |
| Model class | Central | Class range low | Class range high | High case | B200 | Development |
|---|---|---|---|---|---|---|
| Class A | 0.01129 | 0.006972 | 0.01636 | 0.01811 | 0.00989 | 0.01401 |
| Class B | 0.03805 | 0.02453 | 0.04619 | 0.06042 | 0.02665 | 0.04589 |
| Class C | 0.1437 | 0.05654 | 0.2151 | 0.2271 | 0.1478 | 0.1709 |
How much does siting matter for a model served from US Central - Iowa?
Electricity is 88.4% of the class B total here (class A 91%, class C 87.2%), with hardware at 2.7%, construction 1.2% and training 7.7%. Electricity carries most of the 0.0381 kg, so the grid is the biggest lever.
The example company (2,323 million class B tokens a year) emits 88 kg CO₂e from US Central - Iowa. Moving to US South - Southeast would save 6.8 kg (7.7%) or US South Central - Texas would save 16 kg (18%).
| Region | Grid g per kWh | Class A | Class B | Class C |
|---|---|---|---|---|
| US South - Southeast | 431 | 2.08 | 6.8 | 25.3 |
| US South Central - Texas | 375.3 | 4.9 | 16 | 59.7 |
How much water does AI usage consume in US Central - Iowa?
A class B query of 1210 tokens from US Central - Iowa consumes about 0.31 mL of water and a million tokens 0.227 litres, or 0.126 litres without the water attributed to hydropower.
| Input | Value |
|---|---|
| On-site WUE, L per kWh | 0.123 |
| WUE denominator | total site electricity |
| WUE basis as published | withdrawal |
| Withdrawal to consumption | 0.6667 |
| EWIF, L per kWh | 3.104 |
| EWIF without hydro, L per kWh | 1.680 |
| AWARE factor | 3.41 |
| Confidence | derived-site |
| Source | Microsoft; Des Moines (IA) (site); FY25 |
| Model class | On site | Grid electricity | Total | Total without hydro | AWARE-weighted on site |
|---|---|---|---|---|---|
| Class A | 0.00178 | 0.0676 | 0.0693 | 0.0384 | 0.00607 |
| Class B | 0.00583 | 0.221 | 0.227 | 0.126 | 0.0199 |
| Class C | 0.0217 | 0.824 | 0.846 | 0.468 | 0.0741 |
Where do these numbers come from and how do I cite them?
Figures per query are one plain exchange, before the Tier 2b reasoning uplift. Electricity term. GPU energy per token from the ML.ENERGY Leaderboard v3, a facility overhead of 1.20, and grid carbon intensity from EPA eGRID 2023 and Ember 2023. Embodied hardware, data-centre construction and amortised training terms are documented on the methodology page. Water combines on-site cooling water (Li et al. 2025) with the water embedded in grid electricity (Reig et al. 2020). The modelled range of the models inside a class, around the class value, is −41% to +48% for class A, −39% to +24% for class B and −67% to +55% for class C.
Dataset: AI Inference Emission and Resource Factors for Corporate GHG Inventories (SOMA AI Emission Factors (SAEF)), Llopis-Garcia, G., SOMA AI, 19 October 2026, CC BY 4.0, concept DOI 10.5281/zenodo.20443585, which resolves to the latest version (this version 10.5281/zenodo.23371447, earlier version 2 values at 10.5281/zenodo.22767475). Method: Accounting for Purchased AI Inference in Corporate GHG Inventories: A Token-Based Method, arXiv:2606.10660, under peer review.
Partners can fetch any row from the AI factors API, and the whole table is a CSV download.
Cite as "0.0381 kg CO₂e per million tokens, class B, US Central - Iowa, SAEF, 19 October 2026" and link somaai.earth/ai-footprint/factors/us-central.